Page 2 of 20 results (0.003 seconds)

CVSS: 7.8EPSS: 0%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could... • http://www.securityfocus.com/bid/106185 • CWE-693: Protection Mechanism Failure •

CVSS: 6.6EPSS: 0%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Suc... • http://www.securityfocus.com/bid/106185 • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 9.8EPSS: 10%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker with network a... • http://www.securityfocus.com/bid/106185 • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 7.8EPSS: 0%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploit... • http://www.securityfocus.com/bid/106185 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-121: Stack-based Buffer Overflow •

CVSS: 4.3EPSS: 0%CPEs: 6EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulne... • http://www.securityfocus.com/bid/106185 • CWE-248: Uncaught Exception •

CVSS: 7.8EPSS: 0%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation re... • http://www.securityfocus.com/bid/106185 • CWE-125: Out-of-bounds Read CWE-248: Uncaught Exception •

CVSS: 9.8EPSS: 2%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. Th... • http://www.securityfocus.com/bid/106185 • CWE-248: Uncaught Exception •

CVSS: 8.7EPSS: 3%CPEs: 76EXPL: 0

26 Dec 2017 — Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incluid... • https://cert-portal.siemens.com/productcert/html/ssa-141614.html • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.1EPSS: 0%CPEs: 181EXPL: 0

11 May 2017 — Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condi... • http://www.securityfocus.com/bid/98369 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.1EPSS: 2%CPEs: 209EXPL: 0

11 May 2017 — Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Los paquetes de difusión PROFINET DCP especialmente elaborados podrían causar una condición de denegación de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacción humana para recuperar los sistemas. • http://www.securityfocus.com/bid/98369 • CWE-400: Uncontrolled Resource Consumption •