CVE-2022-22732
https://notcve.org/view.php?id=CVE-2022-22732
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf • CWE-668: Exposure of Resource to Wrong Sphere •
CVE-2022-32747
https://notcve.org/view.php?id=CVE-2022-32747
A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf • CWE-290: Authentication Bypass by Spoofing •
CVE-2022-45788
https://notcve.org/view.php?id=CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •
CVE-2022-32519
https://notcve.org/view.php?id=CVE-2022-32519
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0) Existe una vulnerabilidad CWE-257: almacenamiento de contraseñas en un formato recuperable que podría provocar un acceso no deseado a una instancia de DCE cuando un tercero malintencionado lo realiza a través de una red. Productos afectados: Data Center Expert (versiones anteriores a V7.9.0) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-04_+Data_Center_Expert_Security_Notification.pdf&p_Doc_Ref=SEVD-2022-165-04 • CWE-257: Storing Passwords in a Recoverable Format CWE-522: Insufficiently Protected Credentials •
CVE-2022-2988
https://notcve.org/view.php?id=CVE-2022-2988
A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0) Existe una vulnerabilidad CWE-787: escritura fuera de los límites que podría provocar una fuga de información confidencial al acceder a una página web maliciosa desde el software de puesta en marcha. Productos afectados: SoMachine HVAC (versiones anteriores a la V2.1.0), EcoStruxure Machine Expert - HVAC (Versiones anteriores a la V1.4.0) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf • CWE-787: Out-of-bounds Write •