CVE-2020-11999
https://notcve.org/view.php?id=CVE-2020-11999
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Una llamada expuesta de la API permite a los usuarios proporcionar archivos a ser procesados sin saneamiento. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 • CWE-20: Improper Input Validation •
CVE-2020-12034
https://notcve.org/view.php?id=CVE-2020-12034
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. Productos que usan EDS Subsystem: versión 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versión 4.11.00 y anteriores, software RSNetWorx: versión 28.00.00 y anteriores, software Studio 5000 Logix Designer: versión 32 y anteriores) son vulnerables. El EDS Subsystem no proporciona un saneamiento de entrada adecuado, lo que puede permitir a un atacante diseñar archivos EDS especializados para inyectar consultas SQL y manipular la base de datos que almacena los archivos EDS. Esto puede conllevar a condiciones de denegación de servicio. • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •
CVE-2020-12038
https://notcve.org/view.php?id=CVE-2020-12038
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions. Productos que usan EDS Subsystem: versión 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versión 4.11.00 y anteriores, software RSNetWorx: versión 28.00.00 y anteriores , software Studio 5000 Logix Designer: versión 32 y anteriores), es vulnerable. Se presenta una vulnerabilidad de corrupción de memoria en el algoritmo que coincide con los corchetes en el subsistema EDS. • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •
CVE-2020-10642
https://notcve.org/view.php?id=CVE-2020-10642
In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic. En Rockwell Automation RSLinx Classic versiones 4.11.00 y anteriores, un atacante local autenticado podría modificar una clave de registro, lo que podría conllevar a una ejecución de código malicioso usando privilegios system al abrir RSLinx Classic • https://www.us-cert.gov/ics/advisories/icsa-20-100-01 • CWE-732: Incorrect Permission Assignment for Critical Resource •
CVE-2020-6984
https://notcve.org/view.php?id=CVE-2020-6984
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable. Rockwell Automation MicroLogix 1400 Controllers Series B versiones v21.001 y anteriores, Series A, todas las versiones, MicroLogix 1100 Controller, todas las versiones, RSLogix 500 Software versiones v12.001 y anteriores. La función criptográfica usada para proteger la contraseña en MicroLogix es detectable. • https://www.us-cert.gov/ics/advisories/icsa-20-070-06 • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •