CVE-2020-12033 – Rockwell Automation FactoryTalk View SE AddAgent Missing Authentication for Critical Function Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2020-12033
In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges. En Rockwell Automation FactoryTalk Services Platform, todas las versiones, el servicio de host de redundancia (RdcyHost.exe) no comprueba los identificadores suministrados, lo que podría permitir a un atacante adyacente no autenticado ejecutar objetos COM remotos con privilegios elevados This vulnerability allows remote attackers to execute arbitrary code on affected installations of Rockwell Automation FactoryTalk View SE. Authentication is not required to exploit this vulnerability. The specific flaw exists within the AddAgent method. The issue results from a lack of authentication required to instantiate a COM object on the server. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. • https://www.us-cert.gov/ics/advisories/icsa-20-170-04 • CWE-20: Improper Input Validation •
CVE-2020-12028 – Rockwell Automation FactoryTalk View SE
https://notcve.org/view.php?id=CVE-2020-12028
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs. En todas las versiones de FactoryTalk View SEA un atacante autenticado remoto puede ser capaz de usar determinados manejadores para interactuar con los datos en el endpoint remoto, ya que esos controladores no aplican los permisos apropiados. Rockwell Automation recomienda habilitar las funciones de seguridad integradas que se encuentran en FactoryTalk View SE. • http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944 https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05 • CWE-264: Permissions, Privileges, and Access Controls CWE-306: Missing Authentication for Critical Function •
CVE-2020-12005
https://notcve.org/view.php?id=CVE-2020-12005
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Se presenta una vulnerabilidad en la función de comunicación que permite a los usuarios cargar archivos EDS mediante FactoryTalk Linx. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 • CWE-434: Unrestricted Upload of File with Dangerous Type •
CVE-2020-12003
https://notcve.org/view.php?id=CVE-2020-12003
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Una llamada expuesta de la API permite a los usuarios proporcionar archivos a ser procesados sin saneamiento. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
CVE-2020-12001 – Rockwell Automation FactoryTalk Linx CopyRenameProject Directory Traversal Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2020-12001
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. El mecanismo de análisis que procesa determinados tipos de archivos no proporciona un saneamiento de entrada. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 https://www.zerodayinitiative.com/advisories/ZDI-20-733 • CWE-20: Improper Input Validation •