Page 3 of 49 results (0.006 seconds)

CVSS: 7.8EPSS: 0%CPEs: 7EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V14.3.0.1), Teamcenter Visualization V13.3 (Todas las versiones &lt; V13.3.0.12), Teamcenter Visualization V14.0 (Todas las versiones), Teamcenter Visualization V14.1 ( Todas las versiones &lt; V14.1.0.11), Teamcenter Visualization V14.2 (todas las versiones &lt; V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones &lt; V14.3.0.1). La aplicación afectada es vulnerable al Desbordamiento del Búfer al analizar archivos WRL especialmente manipulados. • https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted TIFF file. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones inferiores a la V14.2.0.5), Teamcenter Visualization V13.2 (Todas las versiones inferiores a la V13.2.0.14), Teamcenter Visualization V14.1 (Todas las versiones inferiores a la V14.1.0.10), Teamcenter Visualization V14.2 (Todas las versiones inferiores a la V14.2.0.5). La aplicación afectada contiene una escritura fuera de los límites más allá del final de un búfer asignado mientras analiza un archivo TIFF especialmente diseñado. • https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones inferiores a V14.2.0.5), Teamcenter Visualization V13.2 (Todas las versiones inferiores a V13.2.0.14), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.10), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.5). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada al analizar archivos TIFF especialmente diseñados. • https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf • CWE-125: Out-of-bounds Read •

CVSS: 5.5EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition. Se ha identificado una vulnerabilidad en Parasolid V34.1 (Todas las versiones inferiores a V34.1.258), Parasolid V35.0 (Todas las versiones inferiores a V35.0.254), Parasolid V35.1 (Todas las versiones inferiores a V35.1. 171), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones inferiores a V14.3.0.3). La aplicación afectada contiene una vulnerabilidad de agotamiento de pila al analizar un archivo X_T especialmente diseñado. • https://cert-portal.siemens.com/productcert/html/ssa-407785.html https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 7.8EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Parasolid V34.1 (Todas las versiones inferiores a V34.1.258), Parasolid V35.0 (Todas las versiones inferiores a V35.0.254), Parasolid V35.1 (Todas las versiones inferiores a V35.1. 184), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones inferiores a V14.3.0.3). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada al analizar archivos X_T especialmente diseñados. • https://cert-portal.siemens.com/productcert/html/ssa-407785.html https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf • CWE-125: Out-of-bounds Read •