Page 3 of 28 results (0.016 seconds)

CVSS: 4.6EPSS: 0%CPEs: 16EXPL: 0

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, permite a usuarios locales ganar privilegios mediante el aprovechamiento de controles débiles del acceso a objetos de sistema. • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 6.8EPSS: 0%CPEs: 16EXPL: 0

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. La aplicación de administración del proyecto en Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, tiene una clave de codificación embebida, lo que permite a atacantes remotos obtener información sensible mediante la extracción de esta clave de otra instalación del producto y la posterior utilización de esta clave durante la captura de trafico de la red en puerto TCP 1030. • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf •

CVSS: 7.5EPSS: 97%CPEs: 54EXPL: 16

The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. Las implementaciones de (1) TLS y (2) DTLS en OpenSSL 1.0.1 en versiones anteriores a 1.0.1g no manejan adecuadamente paquetes Heartbeat Extension, lo que permite a atacantes remotos obtener información sensible desde la memoria de proceso a través de paquetes manipulados que desencadenan una sobrelectura del buffer, según lo demostrado mediante la lectura de claves privadas, relacionado con d1_both.c y t1_lib.c, también conocido como bug Heartbleed. An information disclosure flaw was found in the way OpenSSL handled TLS and DTLS Heartbeat Extension packets. A malicious TLS or DTLS client or server could send a specially crafted TLS or DTLS Heartbeat packet to disclose a limited portion of memory per request from a connected client or server. Note that the disclosed portions of memory could potentially include sensitive information such as private keys. • https://www.exploit-db.com/exploits/32764 https://www.exploit-db.com/exploits/32791 https://www.exploit-db.com/exploits/32998 https://www.exploit-db.com/exploits/32745 https://github.com/0x90/CVE-2014-0160 https://github.com/jdauphant/patch-openssl-CVE-2014-0160 https://github.com/caiqiqi/OpenSSL-HeartBleed-CVE-2014-0160-PoC https://github.com/obayesshelton/CVE-2014-0160-Scanner https://github.com/MrE-Fog/CVE-2014-0160-Chrome-Plugin https://github.com/Xyl2k/CVE-2014&# • CWE-125: Out-of-bounds Read CWE-201: Insertion of Sensitive Information Into Sent Data •

CVSS: 7.5EPSS: 0%CPEs: 9EXPL: 0

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Vulnerabilidad de inyección SQL en la pantalla de login en el Web Navigator en Siemens WinCC anterior a 7.2 Update 1, utilizado en SIMATIC PCS7 8.0 SP1 y anteriores y sobre otros productos, permite a atacantes remotos ejecutar comandos SQL de su elección a través de vectores no especificados. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 7.5EPSS: 0%CPEs: 9EXPL: 0

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. La implementación de inicio de sesión en Web Navigator en Siemens WinCC anterior 7.2 Update 1, utilizado en SIMATIC PCS7 8.0 SP1 y anteriores y otros productos, tienen una cuenta embebida en el código (hardcoded), lo que facilita a atacantes remotos obtener acceso a través de una petición no especificada. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf • CWE-255: Credentials Management Errors •