28 results (0.009 seconds)

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges. • https://cert-portal.siemens.com/productcert/pdf/ssa-914026.pdf • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 7.5EPSS: 0%CPEs: 48EXPL: 0

A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. • http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf • CWE-20: Improper Input Validation •

CVSS: 8.2EPSS: 0%CPEs: 4EXPL: 0

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker. Se ha identificado una vulnerabilidad XXE en OPC Foundation UA .NET Sample Code antes del 21-03-2017 y Local Discovery Server (LDS) antes de la versión 1.03.367. Los siguientes productos se han visto afectados por esta vulnerabilidad, entre otros: Siemens SIMATIC PCS7 (todas las versiones V8.1 y anteriores), SIMATIC WinCC (todas las versiones anteriores a V7.4 SP1), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V14 SP1), SIMATIC NET PC Software y SIMATIC IT Production Suite. • http://www.securityfocus.com/bid/100559 http://www.securitytracker.com/id/1039510 https://opcfoundation-onlineapplications.org/faq/SecurityBulletins/OPC_Foundation_Security_Bulletin_CVE-2017-12069.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-535640.pdf • CWE-611: Improper Restriction of XML External Entity Reference •

CVSS: 4.3EPSS: 0%CPEs: 2EXPL: 0

Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. Siemens SIMATIC HMI Comfort Panels anterior a WinCC (TIA Portal) 13 SP1 Upd2 y SIMATIC WinCC Runtime Advanced anterior a WinCC (TIA Portal) 13 SP1 Upd2 permiten a atacantes man-in-the-middle causar una denegación de servicio a través de paquetes manipulados en el puerto TCP 102. • http://www.securityfocus.com/bid/74028 http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf • CWE-20: Improper Input Validation •

CVSS: 6.8EPSS: 0%CPEs: 11EXPL: 0

Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. Siemens SIMATIC HMI Basic Panels 2nd Generation anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), y SIMATIC WinCC 7.x anterior a 7.3 Upd4 permiten a atacantes remotos completar la autenticación mediante el aprovechamiento de conocimiento de un hash de contraseñas sin conocer la contraseña asociada. • http://www.securityfocus.com/bid/74040 http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf • CWE-287: Improper Authentication •