CVE-2024-2893 – Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow
https://notcve.org/view.php?id=CVE-2024-2893
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md https://vuldb.com/?ctiid.257936 https://vuldb.com/?id.257936 https://vuldb.com/?submit.300356 • CWE-121: Stack-based Buffer Overflow •
CVE-2024-2892 – Tenda AC7 setcfm formSetCfm stack-based overflow
https://notcve.org/view.php?id=CVE-2024-2892
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md https://vuldb.com/?ctiid.257935 https://vuldb.com/?id.257935 https://vuldb.com/?submit.300355 • CWE-121: Stack-based Buffer Overflow •
CVE-2024-2891 – Tenda AC7 QuickIndex formQuickIndex stack-based overflow
https://notcve.org/view.php?id=CVE-2024-2891
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md https://vuldb.com/?ctiid.257934 https://vuldb.com/?id.257934 https://vuldb.com/?submit.300354 • CWE-121: Stack-based Buffer Overflow •
CVE-2023-41552
https://notcve.org/view.php?id=CVE-2023-41552
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. • https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md • CWE-787: Out-of-bounds Write •
CVE-2023-41555
https://notcve.org/view.php?id=CVE-2023-41555
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. • https://github.com/peris-navince/founded-0-days/blob/main/formWifiBasicSet/1.md • CWE-787: Out-of-bounds Write •