CVE-2023-38930
https://notcve.org/view.php?id=CVE-2023-38930
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md • CWE-787: Out-of-bounds Write •
CVE-2023-38931
https://notcve.org/view.php?id=CVE-2023-38931
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md • CWE-787: Out-of-bounds Write •
CVE-2023-38933
https://notcve.org/view.php?id=CVE-2023-38933
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md • CWE-787: Out-of-bounds Write •
CVE-2023-38936
https://notcve.org/view.php?id=CVE-2023-38936
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md • CWE-787: Out-of-bounds Write •
CVE-2023-38937
https://notcve.org/view.php?id=CVE-2023-38937
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md • CWE-787: Out-of-bounds Write •