CVE-2023-1143 – CVE-2023-1143
https://notcve.org/view.php?id=CVE-2023-1143
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ActionExeScriptString function. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to execute code in the context of an administrator. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 •
CVE-2023-1137 – CVE-2023-1137
https://notcve.org/view.php?id=CVE-2023-1137
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Electronics InfraSuite Device Master. Authentication is required to exploit this vulnerability. The specific flaw exists within the gateway endpoint, which listens on TCP ports 80 and 443 by default. The issue results from improper access control. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 • CWE-522: Insufficiently Protected Credentials •
CVE-2023-1144 – CVE-2023-1144
https://notcve.org/view.php?id=CVE-2023-1144
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. This vulnerability allows remote attackers to escalate privileges on affected installations of Delta Electronics InfraSuite Device Master. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the Device-Gateway service, which listens on TCP port 3100 by default. The issue results from improper access control. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 • CWE-863: Incorrect Authorization •
CVE-2023-1138 – CVE-2023-1138
https://notcve.org/view.php?id=CVE-2023-1138
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Electronics InfraSuite Device Master. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Device-Gateway service, which listens on TCP port 80 by default. The issue results from improper access control. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 •
CVE-2023-1139 – CVE-2023-1139
https://notcve.org/view.php?id=CVE-2023-1139
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Device-Gateway service, which listens on TCP port 3100 by default. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of an administrator. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 • CWE-502: Deserialization of Untrusted Data •