Page 46 of 750 results (0.004 seconds)

CVSS: 9.1EPSS: 0%CPEs: 12EXPL: 0

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. Una CWE-22: Una vulnerabilidad de Limitación Inapropiada de un Nombre de Ruta a un Directorio Restringido se presenta en los productos Harmony/HMI Configurados por Vijeo Designer (todas las versiones anteriores a V6.2 SP11 ), Vijeo Designer Basic (todas las versiones anteriores a V1.2) o EcoStruxure Machine Expert (todas las versiones anteriores a V2.0) que podría causar una denegación de servicio o un acceso no autorizado a la información del sistema cuando se conecta al Harmony HMI a través de FTP • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.2EPSS: 0%CPEs: 5EXPL: 0

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol. Una CWE-200: Una vulnerabilidad de Exposición de Información Confidencial a un Actor no Autorizado en AccuSine PCS+ / PFV+ (versiones anteriores a V1.6.7) y AccuSine PCSn (versiones anteriores a V2.2.4) que podría permitir a un atacante autenticado acceder al dispositivo por medio del protocolo FTP • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01 https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-05 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 7.5EPSS: 0%CPEs: 49EXPL: 0

A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). Una CWE-476: Una vulnerabilidad de Desreferencia de Puntero NULL que podría causar una Denegación de Servicio en el controlador/simulador del PLC Modicon cuando se actualiza la aplicación del controlador con un archivo de proyecto especialmente diseñado se presenta en Modicon M580 CPU (números de pieza BMEP* and BMEH*, todas las versiones), Modicon M340 CPU (números de pieza BMXP34*, todas las versiones), Modicon MC80 (números de pieza BMKC80*, todas las versiones), Modicon Momentum Ethernet CPU (números de pieza 171CBU*, todas las versiones), PLC Simulator para EcoStruxureª Control Expert, incluidas todas las versiones Unity Pro (antiguo nombre de EcoStruxureª Control Expert, todas las versiones), PLC Simulator para EcoStruxureª Process Expert, incluidas todas las versiones HDCS (antiguo nombre de EcoStruxureª Process Expert, todas las versiones), Modicon Quantum CPU (números de pieza 140CPU*, todas las versiones), Modicon Premium CPU (números de pieza TSXP5*, todas las versiones) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-04 https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-07 • CWE-476: NULL Pointer Dereference •

CVSS: 6.5EPSS: 0%CPEs: 49EXPL: 0

A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). Una CWE-787: Una vulnerabilidad de Escritura Fuera de Límites que podría causar una Denegación de Servicio en el controlador/simulador del PLC Modicon cuando se actualiza la aplicación del controlador con un archivo de proyecto especialmente diseñado se presenta en Modicon M580 CPU (números de pieza BMEP* y BMEH*, todas las versiones), Modicon M340 CPU (números de pieza BMXP34*, todas las versiones), Modicon MC80 (números de pieza BMKC80*, todas las versiones), Modicon Momentum Ethernet CPU (números de pieza 171CBU*, todas las versiones), PLC Simulator para EcoStruxureª Control Expert, incluidas todas las versiones Unity Pro (antiguo nombre de EcoStruxureª Control Expert, todas las versiones), PLC Simulator para EcoStruxureª Process Expert, incluidas todas las versiones HDCS (antiguo nombre de EcoStruxureª Process Expert, todas las versiones), Modicon Quantum CPU (números de pieza 140CPU*, todas las versiones), Modicon Premium CPU (números de pieza TSXP5*, todas las versiones) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-04 https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-06 • CWE-787: Out-of-bounds Write •

CVSS: 6.5EPSS: 0%CPEs: 49EXPL: 0

A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). UN CWE-125: Una vulnerabilidad de Lectura Fuera de Límites que podría causar una Denegación de Servicio en el controlador/simulador del PLC Modicon cuando se actualiza la aplicación del controlador con un archivo de proyecto especialmente diseñado se presenta en Modicon M580 CPU (números de pieza BMEP* y BMEH*, todas las versiones), CPU Modicon M340 (números de pieza BMXP34*, todas las versiones), Modicon MC80 (números de pieza BMKC80*, todas las versiones), CPU Modicon Momentum Ethernet (números de pieza 171CBU*, todas las versiones), PLC Simulator for EcoStruxureª Control Expert, incluyendo todas las versiones Unity Pro (antiguo nombre de EcoStruxureª Control Expert, todas las versiones), PLC Simulator for EcoStruxureª Process Expert incluyendo todas las versiones HDCS (antiguo nombre de EcoStruxureª Process Expert, todas las versiones), Modicon Quantum CPU (números de pieza 140CPU*, todas las versiones), Modicon Premium CPU (números de pieza TSXP5*, todas las versiones) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-04 https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-05 • CWE-125: Out-of-bounds Read •