Page 47 of 750 results (0.007 seconds)

CVSS: 6.5EPSS: 0%CPEs: 49EXPL: 0

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). Una CWE-119: Una vulnerabilidad de Restricción Inapropiada de Operaciones dentro de los Límites de un Búfer de Memoria que podría causar una Denegación de Servicio en el controlador/simulador del PLC Modicon cuando se actualiza la aplicación del controlador con un archivo de proyecto especialmente diseñado se presenta en Modicon M580 CPU (números de pieza BMEP* and BMEH*, todas las versiones), Modicon M340 CPU (números de pieza BMXP34*, todas las versiones), Modicon MC80 (números de pieza BMKC80*, todas las versiones), Modicon Momentum Ethernet CPU (números de pieza 171CBU*, todas las versiones), PLC Simulator for EcoStruxureª Control Expert, incluyendo todas las versiones Unity Pro (antiguo nombre de EcoStruxureª Control Expert, todas las versiones), PLC Simulator for EcoStruxureª Process Expert incluyendo todas las versiones HDCS (antiguo nombre de EcoStruxureª Process Expert, todas las versiones), Modicon Quantum CPU (números de pieza 140CPU*, todas las versiones), Modicon Premium CPU (números de pieza TSXP5*, todas las versiones) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-04 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-427: Uncontrolled Search Path Element vulnerability exists in GP-Pro EX,V4.09.250 and prior, that could cause local code execution with elevated privileges when installing the software. Una CWE-427: Se presenta una vulnerabilidad de Elemento de Ruta de Búsqueda no Controlada en GP-Pro EX, versiones V4.09.250 y anteriores, que podría causar una ejecución de código local con privilegios elevados cuando se instala el software • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-03 • CWE-427: Uncontrolled Search Path Element •

CVSS: 7.5EPSS: 0%CPEs: 12EXPL: 0

A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get knowledge of charging station user account credentials using dictionary attacks techniques. A CWE-759: Se presenta una vulnerabilidad de Uso de un Hash Unidireccional sin Salt en EVlink City (EVC1S22P4 / EVC1S7P4 todas las versiones anteriores a R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 todas las versiones anteriores a R8 V3.4.0.1), y EVlink Smart Wallbox (EVB1A todas las versiones anteriores a R8 V3.4.0.1) que podría conllevar a un atacante a obtener conocimiento de las credenciales de la cuenta de usuario de la estación de carga usando técnicas de ataque de diccionario • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 • CWE-916: Use of Password Hash With Insufficient Computational Effort •

CVSS: 6.5EPSS: 0%CPEs: 12EXPL: 0

A CWE-620: Unverified Password Change vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker connected to the charging station web server to modify the password of a user. A CWE-620: Se presenta una vulnerabilidad de Cambio de Contraseña No Comprobada en EVlink City (EVC1S22P4 / EVC1S7P4 todas las versiones anteriores a R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 todas las versiones anteriores a R8 V3.4.0.1), y EVlink Smart Wallbox (EVB1A todas las versiones anteriores a R8 V3.4.0.1) que podría permitir a un atacante conectado al servidor web de la estación de carga modificar la contraseña de un usuario • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 • CWE-620: Unverified Password Change •

CVSS: 10.0EPSS: 0%CPEs: 12EXPL: 0

A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server. A CWE-798: Se presenta una vulnerabilidad de uso de Credenciales Embebidas en EVlink City (EVC1S22P4 / EVC1S7P4 todas las versiones anteriores a R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 todas las versiones anteriores a R8 V3.4.0.1), y EVlink Smart Wallbox (EVB1A todas las versiones anteriores a R8 V3.4.0.1 ) que podría permitir a un atacante alcanzar privilegios administrativos no autorizados cuando se accede al servidor web de la estación de carga • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 • CWE-798: Use of Hard-coded Credentials •