Page 5 of 39 results (0.004 seconds)

CVSS: 7.8EPSS: 0%CPEs: 21EXPL: 0

A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). Se ha identificado una vulnerabilidad en NX 1953 Series (Todas las versiones anteriores a V1973.3700), NX 1980 Series (Todas las versiones anteriores a V1988), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). La aplicación afectada contiene una vulnerabilidad de uso después de libre al analizar archivos OBJ. • https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-1119 • CWE-416: Use After Free •

CVSS: 4.3EPSS: 0%CPEs: 13EXPL: 0

A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703). Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). La aplicación afectada es vulnerable a una lectura fuera de límites más allá del final de un búfer asignado al analizar archivos JT. • https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-740908.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-1118 • CWE-125: Out-of-bounds Read •

CVSS: 4.3EPSS: 0%CPEs: 13EXPL: 0

A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565). Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). La aplicación afectada es vulnerable a una lectura fuera de límites más allá del final de un búfer asignado al analizar archivos JT. • https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-740908.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-1117 • CWE-125: Out-of-bounds Read •

CVSS: 7.1EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations. Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El archivo plmxmlAdapterIFC.dll contiene una lectura fuera de límites al analizar los archivos IFC suministrados por el usuario, lo que podría dar lugar a una lectura más allá del final de un búfer asignado. • https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El adaptador IFC de la aplicación afectada contiene una vulnerabilidad de uso después de libre que podría activarse mientras se analizan los archivos IFC suministrados por el usuario. • https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf • CWE-416: Use After Free •