Page 6 of 39 results (0.008 seconds)

CVSS: 7.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP5), Teamcenter Visualization (Todas las versiones anteriores a V13.2). • https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-867 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13424) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP5), Teamcenter Visualization (Todas las versiones anteriores a V13.2). • https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-866 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13423) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP5), Teamcenter Visualization (Todas las versiones anteriores a V13.2). • https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-865 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP5), Teamcenter Visualization (Todas las versiones anteriores a V13.2). • https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-864 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 18EXPL: 0

A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049) Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP4). • https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06 • CWE-787: Out-of-bounds Write •