CVE-2024-30190
https://notcve.org/view.php?id=CVE-2024-30190
A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0). This CVE refers to Scenario 2 "Abuse the queue for network disruptions" of CVE-2022-47522. Affected devices can be tricked into enabling its power-saving mechanisms for a victim client. This could allow a physically proximate attacker to execute disconnection and denial-of-service attacks. • https://cert-portal.siemens.com/productcert/html/ssa-457702.html • CWE-290: Authentication Bypass by Spoofing •
CVE-2024-30189
https://notcve.org/view.php?id=CVE-2024-30189
A vulnerability has been identified in SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) (All versions), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) (All versions), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) (All versions), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) (All versions), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) (All versions), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) (All versions), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) (All versions), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) (All versions), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) (All versions), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) (All versions), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) (All versions), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) (All versions), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) (All versions), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) (All versions), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) (All versions), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) (All versions), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) (All versions), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) (All versions), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) (All versions), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) (All versions), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) (All versions), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) (All versions), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) (All versions), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) (All versions), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) (All versions), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) (All versions), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) (All versions), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) (All versions), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) (All versions), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) (All versions). This CVE refers to Scenario 1 "Leak frames from the Wi-Fi queue" of CVE-2022-47522. Affected devices queue frames in order to subsequently change the security context and leak the queued frames. This could allow a physically proximate attacker to intercept (possibly cleartext) target-destined frames. • https://cert-portal.siemens.com/productcert/html/ssa-457702.html • CWE-290: Authentication Bypass by Spoofing •
CVE-2023-50821
https://notcve.org/view.php?id=CVE-2023-50821
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V9.1 (todas las versiones < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (todas las versiones < V19 Update 1), SIMATIC WinCC V7.5 (todas las versiones < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (todas las versiones < V8.0 Update 5). Los productos afectados no validan correctamente la entrada proporcionada en el cuadro de diálogo de inicio de sesión. • https://cert-portal.siemens.com/productcert/html/ssa-730482.html • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2022-32257
https://notcve.org/view.php?id=CVE-2022-32257
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution. Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (todas las versiones < V3.2). La aplicación afectada consiste en un servicio web que carece de un control de acceso adecuado para algunos de los endpoints. • https://cert-portal.siemens.com/productcert/html/ssa-576771.html • CWE-284: Improper Access Control •
CVE-2024-22045
https://notcve.org/view.php?id=CVE-2024-22045
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.1 SP1). The product places sensitive information into files or directories that are accessible to actors who are allowed to have access to the files, but not to the sensitive information. This information is also available via the web interface of the product. Se ha identificado una vulnerabilidad en SINEMA Remote Connect Client (todas las versiones < V3.1 SP1). El producto coloca información confidencial en archivos o directorios a los que pueden acceder los actores a quienes se les permite tener acceso a los archivos, pero no a la información confidencial. • https://cert-portal.siemens.com/productcert/html/ssa-653855.html • CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory •