CVE-2018-17905 – OMRON CX-Supervisor SCS File Parsing Memory Corruption Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2018-17905
When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with a specific byte, memory corruption may occur within a specific object. Al procesar archivos de proyecto en Omron CX-Supervisor en versiones 3.4.1.0 y anteriores y falsificando un byte en concreto, podría ocurrir una corrupción de memoria en un objeto específico. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-Supervisor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. • http://www.securityfocus.com/bid/105691 https://ics-cert.us-cert.gov/advisories/ICSA-18-290-01 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
CVE-2018-17913 – OMRON Industrial Automation CX-Supervisor CSNewDataSets Type Confusion Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2018-17913
A type confusion vulnerability exists when processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, which may allow an attacker to execute code in the context of the application. Existe una vulnerabilidad de confusión de tipos al procesar archivos de proyecto en Omron CX-Supervisor en versiones 3.4.1.0 y anteriores, lo que podría permitir que un atacante ejecute código en el contexto de la aplicación. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-Supervisor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of PAG files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. • http://www.securityfocus.com/bid/105691 https://ics-cert.us-cert.gov/advisories/ICSA-18-290-01 • CWE-704: Incorrect Type Conversion or Cast •
CVE-2018-7514 – OMRON CX-One SBA File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2018-7514
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a stack-based buffer overflow. El análisis sintáctico de archivos de proyecto mal formados en Omron CX-One, en versiones 4.42 y anteriores, incluyendo las siguientes aplicaciones: CX-FLnet, en versiones 1.00 y anteriores; CX-Protocol, en versiones 1.992 y anteriores; CX-Programmer, en versiones 9.65 y anteriores; CX-Server, en versiones 5.0.22 y anteriores; Network Configurator, en versiones 3.63 y anteriores y Switch Box Utility, en versiones 1.68 y anteriores, podría provocar un desbordamiento de búfer basado en pila. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of SBA files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. • https://ics-cert.us-cert.gov/advisories/ICSA-18-100-02 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •
CVE-2018-7530 – OMRON CX-One CX-Protocol CObject Type Confusion Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2018-7530
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may allow the pointer to call an incorrect object resulting in an access of resource using incompatible type condition. El análisis sintáctico de archivos de proyecto mal formados en Omron CX-One, en versiones 4.42 y anteriores, incluyendo las siguientes aplicaciones: CX-FLnet, en versiones 1.00 y anteriores; CX-Protocol, en versiones 1.992 y anteriores; CX-Programmer, en versiones 9.65 y anteriores; CX-Server, en versiones 5.0.22 y anteriores; Network Configurator, en versiones 3.63 y anteriores y Switch Box Utility, en versiones 1.68 y anteriores, podría permitir que el puntero llame a un objeto incorrecto, lo que resulta en un acceso del recurso empleando una condición de tipo incompatible. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PSW files. When parsing a crafted file, the process does not properly validate user-supplied data, which can result in a type confusion condition. • https://ics-cert.us-cert.gov/advisories/ICSA-18-100-02 • CWE-118: Incorrect Access of Indexable Resource ('Range Error') CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •
CVE-2018-8834 – OMRON CX-One CX-FLnet Node Name Heap-based Buffer Overflow Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2018-8834
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a heap-based buffer overflow. El análisis sintáctico de archivos de proyecto mal formados en Omron CX-One, en versiones 4.42 y anteriores, incluyendo las siguientes aplicaciones: CX-FLnet, en versiones 1.00 y anteriores; CX-Protocol, en versiones 1.992 y anteriores; CX-Programmer, en versiones 9.65 y anteriores; CX-Server, en versiones 5.0.22 y anteriores; Network Configurator, en versiones 3.63 y anteriores y Switch Box Utility, en versiones 1.68 y anteriores, podría provocar un desbordamiento de búfer basado en memoria dinámica (heap). This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of FLN files. When parsing the Node Name field, the process does not properly validate the length of user-supplied data prior to copying it to a heap-based buffer. • https://ics-cert.us-cert.gov/advisories/ICSA-18-100-02 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •